My second post is going to be about SNMP checks that apply to the HP ProLaint ML Tower or DL Rack Server, you need to install/configure the Windows SNMP Service, HP Insight Management Agents and the HP ProLiant Array Configuration Utility before these OIDs will work.
Drive Array Health Status = 1.3.6.1.4.1.232.3.1.3.0
1 = other, 2= ok, 3 = degraded, 4 = failed
CPU Fans = .1.3.6.1.4.1.232.6.2.6.5.0 (Usually only appliacble to ML350 G5 as the ML350 G6 Variant does not have CPU Fans)
1 = other, 2= ok, 3 = degraded, 4 = failed
ECC Memory Errors Reported = .1.3.6.1.4.1.232.6.2.3.3.0
0 = No Errors, 1 = 1 Error, etc
Power Supply Status = .1.3.6.1.4.1.232.6.2.9.1.0
1 = other, 2= ok, 3 = degraded, 4 = failed
System Fans = .1.3.6.1.4.1.232.6.2.6.4.0
1 = other, 2= ok, 3 = degraded, 4 = failed
System Temperature = .1.3.6.1.4.1.232.6.2.6.1.0
1 = other, 2= ok, 3 = degraded, 4 = failed