Tag Archives: GFIMax

Powershell Execution Policy

Are you having trouble creating or running you Powershell scripts in Windows, remember that you need to adjust the default Powershell Execution Policy to allow the running of your scripts.

You may otherwise receive an error like the one below

File scriptexample.ps1 cannot be loaded because the execution of scripts is disabled on this system. Please see “get-help about_signing” for more details.

It’s very easy to adjust so don’t panic, just find your Powershell shortcut and remember to open it by “Right Clicking” and selecting “Run as administrator”

Next simply paste the line below into powershell, hit enter and then press “Y” and hit Enter one final time.

set-executionpolicy remotesigned

Microsoft Exchange 2007 and 2010 – Messages Queued For Delivery Powershell Script

I’ve been getting into Powershell in a big way the past few months and have put together a script to display the number of queued messages on a Microsoft Exchange 2007 or Microsoft Exchange 2010 Server.  Under normal conditions your mail queue should really be empty most of the time so lots of queued messages is indicative of a problem.

 

$GETMQFD = Get-Counter ‘\MSExchangeTransport Queues(*)\Messages Queued For Delivery’

$MQFD = $GETMQFD.CounterSamples |Select-Object CookedValue

If ($MQFD.CookedValue | Where {$_ -eq 0})

{

Write-Host $MQFD.CookedValue Messages Queued for Delivery

}

Else

{

Write-Host “No Messages Queued For Delivery”

}

 

If you are using a Server Monitoring package such as GFI Max Remote Management then you can insert Exit Codes (i.e. Exit 1 or Exit 0).  This is placed after the output (i.e. Write-Host “No Messages Queued For Delivery”) to generate an onscreen error or success if one of the two conditions is met.

HP ProLiant ML Tower and DL RackMount Server – SNMP RAID and Health Checks

My second post is going to be about SNMP checks that apply to the HP ProLaint ML Tower or DL Rack Server, you need to install/configure the Windows SNMP Service, HP Insight Management Agents and the HP ProLiant Array Configuration Utility before these OIDs will work.

Drive Array Health Status = 1.3.6.1.4.1.232.3.1.3.0
1 = other, 2= ok, 3 = degraded, 4 = failed

CPU Fans = .1.3.6.1.4.1.232.6.2.6.5.0 (Usually only appliacble to ML350 G5 as the ML350 G6 Variant does not have CPU Fans)
1 = other, 2= ok, 3 = degraded, 4 = failed

ECC Memory Errors Reported = .1.3.6.1.4.1.232.6.2.3.3.0
0 = No Errors, 1 = 1 Error, etc

Power Supply Status = .1.3.6.1.4.1.232.6.2.9.1.0
1 = other, 2= ok, 3 = degraded, 4 = failed

System Fans = .1.3.6.1.4.1.232.6.2.6.4.0
1 = other, 2= ok, 3 = degraded, 4 = failed

System Temperature = .1.3.6.1.4.1.232.6.2.6.1.0
1 = other, 2= ok, 3 = degraded, 4 = failed