Tag Archives: “Logical Drive Status”

Fujitsu Primergy Servers – SNMP RAID and Server Health Checks

This next post is very useful for owners of Fujitsu or Fujitsu Siemens Primergy Servers, it highlights how you can monitor the status of your servers general Health and RAID Status.  To utilise these checks you will need to have the Windows SNMP Service installed and configured.  You will also need to download and install the Fujitsu ServerView RAID Manager and the Fujitsu ServerView Agent for Windows.

These OIDs can be used with your existing Server Monitoring Software such as GFI Max Remote Management or Spiceworks to provide upto the minute information.

Logical Drive Status (Array 1) = 1.3.6.1.4.1.231.2.49.1.6.2.1.10.1.1

1 = unknown, 2 = ok, 3 = degraded, 4 = offline, 5 = rebuilding, 6 = verifying, 7 = initializing, 8 = morphing, 9 = partially degraded

Logical Drive Status (Array 2) = 1.3.6.1.4.1.231.2.49.1.6.2.1.10.1.2

1 = unknown, 2 = ok, 3 = degraded, 4 = offline, 5 = rebuilding, 6 = verifying, 7 = initializing, 8 = morphing, 9 = partially degraded

If you have more than two Logical Drives (i.e. 4 x RAID 1 Sets) then simply substitute the last number of the above OID with 3 or 4, etc to reference the next Logical Drive

Number of Logical Drives = 1.3.6.1.4.1.231.2.49.1.6.1.0

1 = 1 Logical Drive, 2 = 2 Locagical Drives, 3 = 3 Locagical Drives, etc

Number of Physical Drives = 1.3.6.1.4.1.231.2.49.1.5.1.0

1 = 1 Physical Drive, 2 = 2 Physical Drives, 3 = 3 Physical Drives, etc

Power Supply Status = 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.2.0

1 = unknown, 2 = ok, 3 = degraded, 4 = critical

Temperature Sensor Ambient = 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.3.0.11

1 = unknown, 2 = sensor-disabled, 3 = ok, 4 = sensor-fail, 5 = warning-temp-warm, 6 = warning-temp-cold, 7 = critical-temp-warm, 8 = critical-temp-cold, 9 = damage-temp-warm

Temperature Sensor CPU (1) = 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.3.0.1

1 = unknown, 2 = sensor-disabled, 3 = ok, 4 = sensor-fail, 5 = warning-temp-warm, 6 = warning-temp-cold, 7 = critical-temp-warm, 8 = critical-temp-cold, 9 = damage-temp-warm

Temperature Sensor CPU (2) = 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.3.0.2

1 = unknown, 2 = sensor-disabled, 3 = ok, 4 = sensor-fail, 5 = warning-temp-warm, 6 = warning-temp-cold, 7 = critical-temp-warm, 8 = critical-temp-cold, 9 = damage-temp-warm

Please feel free to comment if you have any other useful OIDs or require further assistance

HP ML110 G5 – SNMP RAID Checks

My first post is going to be about SNMP for the HP ML110 G5 Server, you need to install/configure the Windows SNMP Service and the HP Storage Manager before these OIDs will work.

ML110 G5 – Controller Status = 1.3.6.1.4.1.795.14.1.201.1.1.15.1

Status Codes: 1 = other, 2 = unknown, 3 = ok, 4 = non-critical, 5 = critical, 6 = nonrecoverable

ML110 G5 – Logical Drive Status (Array 1) = 1.3.6.1.4.1.795.14.1.400.1.1.11.1

Status Codes: 1 = other, 2 = unknown, 3 = ok, 4 = non-critical, 5 = critical, 6 = nonrecoverable

ML110 G5 – Logical Drive Status (Array 2) = 1.3.6.1.4.1.795.14.1.400.1.1.11.2

Status Codes: 1 = other, 2 = unknown, 3 = ok, 4 = non-critical, 5 = critical, 6 = nonrecoverable

ML110 G5 – Array Type (Array 1) = 1.3.6.1.4.1.795.14.1.1000.1.1.4.1

Status Codes: 1 = unknown, 2 = other, 3 = raid 0, 4 = raid 1, 10 = raid 10

ML110 G5 – Array Type (Array 2) = 1.3.6.1.4.1.795.14.1.1000.1.1.4.2

Status Codes: 1 = unknown, 2 = other, 3 = raid 0, 4 = raid 1, 10 = raid 10

Hope you find my first post helpful.