Fujitsu Primergy Servers – SNMP RAID and Server Health Checks

This next post is very useful for owners of Fujitsu or Fujitsu Siemens Primergy Servers, it highlights how you can monitor the status of your servers general Health and RAID Status.  To utilise these checks you will need to have the Windows SNMP Service installed and configured.  You will also need to download and install the Fujitsu ServerView RAID Manager and the Fujitsu ServerView Agent for Windows.

These OIDs can be used with your existing Server Monitoring Software such as GFI Max Remote Management or Spiceworks to provide upto the minute information.

Logical Drive Status (Array 1) = 1.3.6.1.4.1.231.2.49.1.6.2.1.10.1.1

1 = unknown, 2 = ok, 3 = degraded, 4 = offline, 5 = rebuilding, 6 = verifying, 7 = initializing, 8 = morphing, 9 = partially degraded

Logical Drive Status (Array 2) = 1.3.6.1.4.1.231.2.49.1.6.2.1.10.1.2

1 = unknown, 2 = ok, 3 = degraded, 4 = offline, 5 = rebuilding, 6 = verifying, 7 = initializing, 8 = morphing, 9 = partially degraded

If you have more than two Logical Drives (i.e. 4 x RAID 1 Sets) then simply substitute the last number of the above OID with 3 or 4, etc to reference the next Logical Drive

Number of Logical Drives = 1.3.6.1.4.1.231.2.49.1.6.1.0

1 = 1 Logical Drive, 2 = 2 Locagical Drives, 3 = 3 Locagical Drives, etc

Number of Physical Drives = 1.3.6.1.4.1.231.2.49.1.5.1.0

1 = 1 Physical Drive, 2 = 2 Physical Drives, 3 = 3 Physical Drives, etc

Power Supply Status = 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.2.0

1 = unknown, 2 = ok, 3 = degraded, 4 = critical

Temperature Sensor Ambient = 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.3.0.11

1 = unknown, 2 = sensor-disabled, 3 = ok, 4 = sensor-fail, 5 = warning-temp-warm, 6 = warning-temp-cold, 7 = critical-temp-warm, 8 = critical-temp-cold, 9 = damage-temp-warm

Temperature Sensor CPU (1) = 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.3.0.1

1 = unknown, 2 = sensor-disabled, 3 = ok, 4 = sensor-fail, 5 = warning-temp-warm, 6 = warning-temp-cold, 7 = critical-temp-warm, 8 = critical-temp-cold, 9 = damage-temp-warm

Temperature Sensor CPU (2) = 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.3.0.2

1 = unknown, 2 = sensor-disabled, 3 = ok, 4 = sensor-fail, 5 = warning-temp-warm, 6 = warning-temp-cold, 7 = critical-temp-warm, 8 = critical-temp-cold, 9 = damage-temp-warm

Please feel free to comment if you have any other useful OIDs or require further assistance

Powershell Execution Policy

Are you having trouble creating or running you Powershell scripts in Windows, remember that you need to adjust the default Powershell Execution Policy to allow the running of your scripts.

You may otherwise receive an error like the one below

File scriptexample.ps1 cannot be loaded because the execution of scripts is disabled on this system. Please see “get-help about_signing” for more details.

It’s very easy to adjust so don’t panic, just find your Powershell shortcut and remember to open it by “Right Clicking” and selecting “Run as administrator”

Next simply paste the line below into powershell, hit enter and then press “Y” and hit Enter one final time.

set-executionpolicy remotesigned